33/RV_Extraktor-Steuergeräte_2021
Opening date
August 19, 2021
Closing date
September 16, 2021
Type
Forthcoming tender
Research Facility
FAIR
Vacuum measuring technique is of special importance in the FAIR and GSI accelerator facilities. On
the one hand, monitoring the vacuum pressures in the beam tubes is indispensable for the
assessment of the generated vacuum quality, which defines the beam losses and thus ultimately the
beam life time. On the other hand, vacuum measuring techniques will be used as an input for the
interlock system of the machines and is important for the detection and localization of potential
leaks. Reliability and durability of the vacuum measurement technology used are therefore
important prerequisites for trouble-free operation of the accelerator vacuum systems. The vacuum
measurement at FAIR and GSI involves the measurement of pressures ranging from atmospheric
pressure down to the operating pressure required in the particular machines. Operating pressures
GSI Helmholtzzentrum für
Schwerionenforschung GmbH
Planckstraße 1
64291 Darmstadt
www.gsi.de
Seite 2 von 2 33/RV_Extraktor-Steuergeräte_2021
range from the upper to the deep UHV range (depending on the respective machine). Vacuum
pressures of ≤ 10-11 mbar are partly generated and maintained in the bakeable ring sections of the
SIS100 as well as in the high energy beam transfer sections from and to the SIS100. As only hot
cathode gauges of extractor type allow pressure measurements in this vacuum range (see ISO 3529-3
for gauge classification), this specific gauge type is planned to be used for monitoring the vacuum
conditions in these beam lines. Due to radiation environmental issues, the FAIR and GSI facilities
require vacuum gauges without on-board electronics on the gauge head (i.e. passive gauges), only.
The controllers for the gauges will be located in dedicated supply rooms properly shielded from the
high radiation areas of the accelerator tunnels. The controllers must be compatible with remote
connection to the gauges with the use of cable lengths of up to 100 m. It shall provide analogue